Dementia Control Unit (DCU)





The Dementia Control Unit (DCU) is capable of determining when a residents activities fall outside selected parameters, and is able to automatically notify care providers. The DCU provides for all nurse call related connections within the room including Call Buttons and sensors. Sensors include bedroom PIR, ensuite PIR, front door, curtain PIR, external door reed switches and enuresis sensors. The DCU integrates into bedroom and ensuite lighting controls, enabling lights to be turned on automatically if the resident gets out of bed or if they enter the ensuite and turn off all the lights once they get back into bed. The DCU has three states of operation: day, night or manual mode. Each mode is individually programmable to meet the needs of each resident. Each of the sensors is programmable to recognise an alarm as being active instantly or after a predetermined period, to allow for the alarm condition to be reset within a designated period. This period is programmable for day, night or manual mode. Each sensor is programmable for an activation delay of between 0 and 40 minutes, to provide sufficient time for residents to exit their bed, visit the ensuite and return. The DCU supports four overdoor lights and three outputs for activation of lighting. Any callpoint activations or sensor activations will be able to turn on any combination of overdoor lights and lighting controls, to provide automatic assistance to the resident. The DCU provides 12 Volt DC Power, to provide support for third party sensors such as Reed Switches, PIR Sensors, Bed Exit Alarms and Enuresis Sensors. Compatibility: Compatible with Advance Care nurse call systems only. Installation: A qualified technician is required to install this product. NurseCallOnline can assist with installation of this product. Call us today for more information.

Features

  • Out of Bed, Out of Bed too long, Entered bathroom, In bathroom too long, Room Exit, Exterior Door Exit.
  • Design & Specifications: Height 115mm, Width 75mm, Depth 12mm, Weight 86 grams, Mounting Method Wall surface, Mount Plate Equivalent to Clipsal 2000 plate, Wall Box Size Standard Australian, Housing Wall Box, Connectors RJ45, Temperature -20 deg C to 50 deg C, Humidity Range 0 to 90%. Designed to comply with: AS 3811:1998 Hard-wired patient alarm systems for hospitals, AS 2999:1989 Alarm systems for the elderly and other persons at risk, C-Tick Electromagnetic compatibility.

Tender Specifications: Supply and install the Dementia Management Unit where indicated on the drawings. The flush mounted Dementia Management Unit shall be manufactured of polycarbonate plastic with a snap on cover to conceal the fixings. The administration buttons will be constructed of polycarbonate resin thermoplastic and comply with IP53 to ensure suitability for residential cleaning. The system shall be capable of determining when a residents activities fall outside the selected parameters, and is therefore likely to require assistance by the care staff. Access to the Dementia Management Unit will be restricted through the use of a proximity key, to ensure that only trained nursing staff are permitted to alter the system programming and/or activate/deactivate the profile. The Dementia Management Unit consists of a Room Bus Module and a passage mounted room profiler interface. The Room Bus Module allows for all nurse call related connections within the room including all nurse call related Call Buttons and room sensors. Sensors include bedroom PIR, ensuite PIR, front door, curtain PIR, external door reed switch and enuresis sensor. The Room Bus Module allows for interfacing to bedroom and ensuite lighting. This enables lights to be turned on automatically if the resident exits the bed or if they enter the ensuite and turn off all the lights once they get back into bed. The Dementia Management Unit has three states of operation day, night or manual mode. Each mode is individually programmable to meet the needs of each resident. Each of the sensors will be programmable to recognise an alarm as being active instantly or after a predetermined period, to allow for the alarm condition to be reset within a designated period. This predetermined period will be programmable for day, night or manual mode of operation. Each sensor will be programmable for activation between 0 and 40 minutes, to provide sufficient time for residents to exit their bed, visit the ensuite and return. The Dementia Management Unit will support four overdoor lights and three outputs, for activation of internal lighting controls. Any callpoint activations or sensor activations will be able to turn on any combination
of overdoor lights and lighting controls, to provide automatic assistance to the resident. The Dementia Management Unit will provide a current limited 12 Volt DC Power Supply, to provide support for third party sensors such as Reed Switches, Passive Infrared Motion (PIR) Sensors, Bed Exit Alarms and Enuresis Sensors.